SNMP get type defines the SNMP polling method used by a universal device poller (UDP) to get the device’s object ID (OID) values.
Which SNMP get type retrieves values from a particular column?

  • A. column
  • B. data
  • C. next
  • D. table


Answer : D

It is noted in flow source view that some devices are showing “never received” in the last received flow column. It is verified that the flows are not being blocked by a firewall. What is the likely cause?

  • A. flows are IPv6 and not supported by the network monitoring features
  • B. interface is no longer monitored by the network monitoring features
  • C. node is no longer monitored by the monitoring features
  • D. a primary field of data is missing and being dropped


Answer : D

Which two of the following flow technologies are supported? (Choose two.)

  • A. GFIow
  • B. HFIow
  • C. J-Flow
  • D. sFlow


Answer : CD

One NetPath probe is showing a “no data found” error, however other probes are returning data without issue. What is the most likely resolution?

  • A. add the probe ID to the engines table manually
  • B. delete the probe, reinstall the agent manually, and re-add the probe
  • C. probe was added in NetPath without an agent installed on its node
  • D. restart the SolarWinds agent service on the node


Answer : B

Which two of the following Windows versions are supported for log collection in hybrid cloud observability? (Choose two.)

  • A. Windows 10
  • B. Windows server 2012
  • C. Windows server 2019
  • D. Windows Vista


Answer : AC

From which two of the following locations can the status of the flow collector service be checked? (Choose two.)

  • A. flow and CBQoS sources
  • B. NetFlow collector services
  • C. NetFlow settings
  • D. top XX receivers


Answer : BC

Which two of the following processing policies are processed independently and at the same time? (Choose two.)

  • A. global post
  • B. global pre
  • C. syslog
  • D. traps


Answer : CD

Which tool presents live flow traffic data sourced from / to a main polling engine server, providing basic insight into traffic on the main polling engine?

  • A. CBQoS / flow sources
  • B. collector service
  • C. flow navigator
  • D. local NetFlow source


Answer : D

Which method is used to add new UPS battery status statistics onto an existing node that does not have the default value polled?

  • A. create new custom device poller
  • B. custom statistics cannot be added to an existing node
  • C. define custom statistic with universal device poller (UnDP)
  • D. update SolarWinds’ MIB database


Answer : C

SNMP traps are being received from several devices. While most of the traps are normal, traps from one of the devices contain fields that are unreadable. The device is not being monitored in any other way. Which two of the following points should be checked? (Choose two.)

  • A. Verify the device is not using SNMPv3 and is added as a node.
  • B. Verify the device supports hybrid cloud observability (HCO).
  • C. Verify the device supports SNMP and is added as a node.
  • D. Verify the device’s MIB file is in SolarWinds’ MIB database.


Answer : CD

What is the unit of data used for alerting on flows?

  • A. bPs
  • B. gps
  • C. mbps
  • D. ms


Answer : A

On a single node, one or more interfaces are showing an “unknown” status. What is the best way to resolve the issue?

  • A. Change node’s polling method to ICMP.
  • B. Delete and rediscover the node showing affected interfaces.
  • C. Delete and re-add the affected interfaces.
  • D. Verify the interfaces are assigned to SolarWinds’ native poller.


Answer : C

What is the correct sequence of steps to create a device studio poller?

  • A. Assign the poller to node, select the technology, specify the data source, and save the poller.
  • B. Select the technology, assign the poller to node, specify the data source, and save the poller.
  • C. Select the technology, specify the data source, assign the poller to node, and save the poller.
  • D. Select the technology, specify the data source, save the poller, and assign the poller to node.


Answer : D

Network wide node and interface changes were recently made to several fields including names and IP addresses on nodes, captions, and aliases for their interfaces. Those changes are not updated in the hybrid cloud observability web console, even if a new polling is forced.
What should be done to resolve the issue?

  • A. Delete and re-add each of the nodes and their interfaces.
  • B. Manually update the changed information in each poller.
  • C. Run a rediscovery on both nodes and interfaces to refresh the data.
  • D. Run a rediscovery on the node, which will also update the interfaces.


Answer : C

Which additional polling method is needed after adding Cisco ASA and Cisco Nexus for SNMP monitoring?

  • A. API
  • B. CLI
  • C. iControl
  • D. WMI


Answer : B

Page:    1 / 11   
Exam contains 151 questions

Talk to us!


Have any questions or issues ? Please dont hesitate to contact us

Certlibrary.com is owned by MBS Tech Limited: Room 1905 Nam Wo Hong Building, 148 Wing Lok Street, Sheung Wan, Hong Kong. Company registration number: 2310926
Certlibrary doesn't offer Real Microsoft Exam Questions. Certlibrary Materials do not contain actual questions and answers from Cisco's Certification Exams.
CFA Institute does not endorse, promote or warrant the accuracy or quality of Certlibrary. CFA® and Chartered Financial Analyst® are registered trademarks owned by CFA Institute.
Terms & Conditions | Privacy Policy